C4 GSM Gate and Roller Shutter Control PCB Wiring

C4 Mobile Phone Shutter Controller

The shutter can be opened and closed by calling the SIM card number or sending a SMS text to the SIM card number.  The setup and wiring depends on the configuration of your shutter control panel.

Gate or Garage Door with one ‘Open’ terminal

GSM Roller Shutter Controller

Simple Open Input Controller

For gates and garage door openers with just one ‘open’ connection just the # terminals are used.  Connections are made from the COM# terminal and NO~ terminal.

The following commands are used (sent in a SMS to the SIM card number):

Master <your number>.           …sets your phone up as with admin rights

Add <number>.                       …adds more numbers to the system

Open                                       …open and closes the gate/door

Latch                                       …holds the door/gate open until ‘OPEN’ or ‘OFF#’ sent

 

Gate or Garage Door with Open and Close Terminals

Phone SMS controller gate roller shutter

C4 to Controller with both Open and Close Terminals

For gates, roller shutters and garage doors with an open and a close terminal the second relay is used.  This allows the GSM unit to close the entry also.

 

The following commands are used (sent in a SMS to the SIM card number):

Master <your number>.           …sets your phone up as with admin rights

Add <number>.                       …adds more numbers to the system

Channel alt                             …allows first call to open shutter, second call to close it

Open                                       …opens the gate/door

Close                                       …closes the gate/door

 

Rlymode ring                           …activates output relays whilst phone is ringing

Rlytime xxx.                              …sets the relay output pulse time to xxx seconds

 

Open/Close send give a pulsed relay output set by the RLYTIME command.  ON*/OFF* and ON#/OFF# activate and deactivate the relay permanently.  Calling the device will operate the relay set by the CHANNEL command (default is #).  CHANNEL ALT will allow one call to operate the # relay and the next to operate the * relay – usefull for opening and closing the shutter.  To operate the shutter only whilst the phone is ringing the RLYMODE RING command is sent.  RLYMODE PULSE return this to the default pulse setting.

The C4 Gate and Rolller Shutter GSM Phone Control PCB is available on our website on the following link C4 Mobile Phone Shutter Controller

Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )