Castle Care 1600 Burglar Alarm to GSM Dialer/SMS Sender Wiring Diagram and Programming

Wiring the Advent Controls GSM Alarm Dialer and SMS sender to the Castle Care 1600 Alarm panel is straight forward.  The bell -ve connection on the panel is used to trigger input A.  The OUT terminal on the alarm panel is used to send a SMS text informing the users when the alarm has been set, unset or both (if desired).

GSM SMS Sender Wiring

GSM Dialer Wiring Diagram

To customise the input alarm message the programmer should send to the dialer:

CustomAL The alarm is sounding.  (don’t forget the full stop!)

If desired a message can be sent when the alarm stops sounding as follows:

Firstly set inlevela to both so a message is sent when the alarm starts and stops:

inlevelA both

Next the alarm stopping message should be set up:

customAH The alarm has be deactivated.   (don’t forget the ‘.’)

If using input B for set/unset notifications you may wish to separate the numbers that receive each message.  You do this by sending the alarm alert message recipients as textnumA:

textnuma <alarm recipient 1>.

textnuma <alarm recipient 2>.  and so on…

For the people who would like to know when the alarm is armed/disarmed you would set as follows:

textnumb <armed recipient 1>.   …and so on

You should also separate the callnumA and callnumBs too.

GSM Dialer programming

Set/Unset Signal

From the above diagram we can see the OUT voltage goes LOW (0v) when set therefore to customise the input B message you send the following text:

custombL The system is armed.

And unset…

custombH The system has been disarmed.

Again you will need to send inlevelb both to receive both messages.

You will also need to tell the alarm panel to output the Set/Unset signal using command 50

GSM Programming

Castle Care Output table

 

Advertisements

PAYG SIM Card Deactivation

When using Pay As You Go (PAYG) SIM cards in equipment such as dialers and gate openers you should be aware that the network may chose to deactivate your SIM card should you not meet the minimum usage requirements.  In the UK the strictest networks require at least a call or text message to be sent once per quarter – Lebara Mobile require 1 call/SMS per 3 28 day calendar months.

For details of the terms and conditions for each network I recommend following this link with an excellent article written on the subject:

http://kenstechtips.com/index.php/payg-inactivity-account-termination-and-credit-expiry

Further details can be found here on the basis for these policies:

https://community.giffgaff.com/t5/Blog/Recycling-mobile-numbers-giffgaff/ba-p/8211666

Our GSM equipment has two SIM card Keep Alive functions which automatically send an SMS or dial a number to keep your SIM card within the terms and conditions of the network.  All products have the Keep Alive Text feature which sends an automated SMS message at user specified intervals to their chosen number.  This is set up as follows:

KAT 07000000000,28.       Sends a keep alive message every 28 days to 07000000000

Dialers and Gate Openers with firmware version 3.18 or later additionally have the ability to dial numbers where a voice call is a requirement.  This is set up using the following command:

KAC 01512834306,80.      Dials 01512834306 every 80 days

Should the call go unanswered it unit will retry 4 times and will then send an SMS to the first master number with the following text ‘KAC@Fail’.  In this case a manual call should be made with the following command:

Dial 01512834306.     …or the number of your choice

Where your network requires a call to be made but your device has firmware prior to F3.18 we recommend setting the Keep Alive Text message to remind you to make a manual call for your required interval using the dial command.  Ensure the call is answered.

Vodafone Dialing Issues 24/07/15

!!Please note this has been resolved by Vodafone (31/07/15).  We would recommend testing your alarm however!!

Last week we were notified by an installer that he was unable to get the dialer to dial mobile numbers using a Vodafone SIM; texting was unaffected.  We replaced the SIM card in the unit for an EE based reseller (Vectone) and the dialer functioned perfectly.

After investigating the cause, we found Vodafone have started to mis-report the call status of an out-bound call (more information below).  The simple resolution is to use an O2 or EE based SIM provider.  We updated the firmware to allow Vodafone to be used, as is, but with some additional commands required:

divert en

With Diverts Enabled the call length is now set by (without divert en it defaults to 5s):

ctime xx.  (the default is 58 seconds)

If you are using a Vodafone SIM in your dialer, run an alarm test to see if your local cell is affected by the issue.  If it is, ensure you have SMS alerts (textnum xxxxxxxx.) set up along with calling alerts.  You will require firmware F3.15 or later for ‘divert enable’ to be effective.

The Issue

To understand the issue we need to look at the information we obtain about the call from the network using the AT+CLCC command.  This command reports back the call status.  Here is an example of how a call is handled using the Vectone EE network SIM:

..+CLCC: 1,0,2,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,2,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,2,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,2,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,2,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,2,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,3,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,3,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,3,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,3,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,0,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,0,0,0,”07930666555″,129,””….OK..
..+CLCC: 1,0,0,0,0,”07930666555″,129,””….OK..
..NO CARRIER….
OK..

The CLCC data is checked every second.  When the dialer is triggered we see the status of the call goes to status 2 (highlighted in red) which is the ‘DIALING’ phase.  This is the time when the call is set up with the network.  After 6 seconds we see the next CLCC report shows the call is now at status 3 ‘ALERTING’ indicating the remote phone is ringing – at this stage the recipient can hear the phone ringing.  When the phone is answered, we see the call goes to status 0; the ‘ACTIVE’ state.  This means the phone has been answered.

Finally, after 3 seconds the call is ended by the recipient and we see ‘NO CARRIER’ is sent by the network.  This is an example of how a call should be handled.

..+CLCC: 1,0,2,0,0,”07830666575″,129,””….OK..
..+CLCC: 1,0,2,0,0,”07830666575″,129,””….OK..
..+CLCC: 1,0,2,0,0,”07830666575″,129,””….OK..
..+CLCC: 1,0,2,0,0,”07830666575″,129,””….OK..
..+CLCC: 1,0,2,0,0,”07830666575″,129,””….OK..
..+CLCC: 1,0,0,0,0,”07830666575″,129,””….OK…
.OK..
..OK..
..+CLCC: 1,0,2,0,0,”01517283167″,129,””….OK..

Above shows how Vodafone have been reporting a Mobile Originated (MO) call since the issue arose.  As before we see the call immediately going to status 2 after a dial command as expected.  However, prior to when the recipient’s phone starts to ring the status of the call is reported at status 0.  When a call goes from status 2 to 0, this is indicative of a call going to voicemail.  Voicemail does not ring out and it is diverted without the ringing phase hence the dialer moves on to the next number as we can see.

This can occur normally with Vodafone as they play a voice message telling the caller to top up credit when credit is low.  However, this behaviour has started to happen on all calls no matter what credit is available and causing the dialer to skip all calls.

The command ‘divert enable’ allows calls to go to a diverted number.  Normally you would not want this as there is no point calling voicemail with the dialer.  However, as there is no accurate way of detecting the status of a call with this Vodafone issue ‘divert enable’ will allow the call to continue.  This command was originally intended for our intercoms to allow mis-resporting (it occasionally happened with some MVNOs like Lyca Mobile) but must be used on an affected Vodafone SIM.

As the length of an alarm dialer call is limited to 5s this is insufficient time for a mobile call to be set up.  Therefore, the firmware we released this week (29/07/15 F3.15) allows the CTIME command to set the length of the call when diverts are enabled.

CTIME xx.

Hopefully this network issue will be resolved shortly by Vodafone.  If this persists and Vodafone is the only available network, we recommend returning the dialer to Advent Controls for a firmware upgrade.  Our latest firmware release allows any future updates to be performed over the internet using GPRS.

Dialer Information Page

Wiring a RISCO WisDom Alarm Panel to the GSM SMS Dialer

The Risco Wireless alarm is unusual in that it operated from a 9V AC supply. It may at first appear to be too low a voltage to operate our dialer, however, once rectified to DC the voltage will be around 12.5V and sufficient to power our board.  To do this simply connect the two AC supply terminals on the RISCO panel to our two VIN terminals.

RISCO WisDom GSM Wiring

Wiring the RISCO WisDom to our GSM Alarm Dialer

WIth the supply coming from the panel being rectified on board the dialer you cannot connect the GND terminals together as usual however there is no need on this alarm as there as two relay outputs on the panel.  The two relay COM terminals are connected together and then wired to the GSM Dialer GND terminal.  The two NO terminals are then wired separately to the A and B inputs if two different messages are required.

The final stage of the process is to program the alarm outputs to do what you require.  We recommend the output connected to our input A is designated as the “Bell Intruder” output.  Input B can be used for any other alert feature like errors/unsetting & setting of the system

GSM Dialer to WisDom Output Programming

Programming Output on Risco WisDom

Click here for a link to the Risco WisDom Alarm Wiring Manual

The Advent Controls GSM Alarm SMS Sender and Dialer is available from the Advent Controls website by click this link

GSM Dialer/SMS Sender to Texecom Premier Elite 24 Alarm

Connection to the Texecom Premier Elite Series of Alarm panels is very straight forward requiring only 3 connections to be made.

Texecom Premier Elite to GSM Dialer SMS Sender

Texecom Premier Elite 24 Wiring Diagram

To power the GSM Dialer you can use the auxiliary output on your Texecom panel.  The positive (+) terminal is connected to one of the VIN terminals (the lower one is best as it has on-board thermal fuse protection) and the negative (-) terminal to GND on the GSM Dialer PCB.  You then connect the ‘BELL’ (bell -ve) terminal to input A or B.

With the Premier Elite range of alarms there is an additional output connection you can wire to the dialer’s second input.  This can be setup using the Texecom menu to send an SMS message for various events.  Below is a summary of the various messages that can be sent to the user/engineer.  You must setup specific recipients for that input i.e. when using input B:

textnumB 07xxxxxxxxx.

And what you would like the message to say:

customB SERVICE REQUIRED.  (Output option 8)

Advent Controls

The GSM Dialler is available from our online shop here

GSM Dialer

GSM Alarm Auto-dialer

00 – ATS Path Fault
This output type activates when a fault is detected with the Alarm Transmission System and deactivates when the fault is cleared.
01 – Mains Power Off
This output type activates when no AC Mains is detected on the control panel and deactivates when mains is detected.
02 – Aux Fuse Blown
This output type activates when the Auxiliary fuse (F1) fails and deactivates when the system is reset.
03 – Bell Tamper
This output type activates when the control panel Bell tamper or an expander input (programmed as Bell tamper) is activated, causing a Tamper alarm on the system, and deactivates when the Tamper alarm is reset.
04 – Auxiliary Tamper
This output type activates when the control panel Aux tamper or an expander input (programmed as Auxiliary tamper) is activated, causing a Tamper alarm on the system, and deactivates when the Tamper alarm is reset.
05 – Panel Lid Tamper
This output type activates whenever the panel cover is removed, causing a Tamper alarm on the system, and deactivates when the Tamper alarm is reset.
06 – Engineer Working
This output type activates whenever an Engineer code is entered to access the programming menu and deactivates when the engineer logs off.
07 – Confirm Devices
This output type activates when the control panel requires devices to be confirmed and deactivates when the devices are confirmed (see page 117 for details).
08 – Service Required
This output type activates when the ‘Service Interval’ timer expires and deactivates when an Engineer code is entered (see page 62 for details).
09 – Bell Fuse Blown
This output type activates when the control panel bell fuse (F4) fails and deactivates when the system is reset.
10 – Battery Fault
This output type activates when the system detects a fault with the stand-by battery, and deactivates when the fault clears.
11 – Battery Test On
This output type activates when the ‘Battery Test’ starts, and deactivates when the test expires (see page 62 for details).
12 – Courtesy Light
This output type activates when the ‘Courtesy’ timer starts, and deactivates when the timer expires (see page 62 for details).
13 – System Open
This output type activates when all areas are unarmed, and deactivates when any area is armed.
14 – Fully Arm
This output type activates when the system is fully armed and deactivates when the system is disarmed.
15 – Digi Failed
This output type activates when the plug-on communicator fails to report to the Alarm Receiving Centre (after 3 dialling attempts), and deactivates the next time the communicator successfully reports to the Alarm Receiving Centre.
16 – Digi Successful
This output type activates when the plug-on communicator successfully reports to the Alarm Receiving Centre and deactivates the next time the communicator is triggered.
17 – Digi Active
This output type activates when the plug-on communicator is triggered and deactivates when the communicator shuts down.

Friedland Response SA5 Alarm connection to GSM Auto Dialer and SMS Sender

Response SA5 GSM Dialer Wiring Connection using Relay

GSM Dialer Connection using Relay

There are 3 ways of connecting the Advent Controls GSM Alarm Dialer to the Friedland Response SA5/SL5 Wireless Alarm panel.  The easiest way is to make use of the output relay on the internal wiring connection header within the Response panel.  By connecting the GSM dialer’s input to the GND terminal through the alarm’s relay NO (Normally Open) and C (Common) terminals the dialer will start calling and sending SMS messages.

Response SA5 GSM Dialer Wiring

Connection using the wired bell output

When using the relay the panel must be programmed to output a signal using the relay when the alarm sounds.  The following is taken from the manual

Relay settings for connecting the Reponse SL5 Burglar Alarm to a GSM Dialer

Response SL5 Relay Config

Setting the relay to 2s if sufficient.  Thanks to Ray Dunne for the information

The second way makes use of the 12v output designed to drive an external wired bell.  Unusually this terminal goes from a high impedance state to +12V when active (alarm sounding).  This is contrary to the requirements of most wired bells which normally are wired to an open collector transistor output which is pulled to 0v (negative edge) when active.

The dialer can be set to look for the positive edge using the following command:

inlevela open      (Firmware F3.11 and earlier) or,

inlevela positive (Firmware F3.12 and later)

As the output is high impedance when not active it will be pulled high by the dialer input source current.  Therefore a resistor should be wired between the Input A terminal and GND to keep the input at 0v when not active.  The resistor should be 470-2000 ohms.  A 470R resistor is normally included with the dialer for this purpose

Finally it is also possible to wire the integral voice dialer to the input as in the Yale alarm video.  When the alarm goes ‘off the hook’ to dial the numbers the GSM dialer sees a connection between input and GND triggering dialing using the GSM network.

The Advent Controls GSM Alarm Dialer is available here

GSM Gate Opener A3.02

Advent Controls A3.02

GSM Alarm Auto-dialer and SMS Sender to Texecom Compact R8

Connection to the Texecom Compact R8 Burglar Alarm panel is very straight forward requiring only 3 connections to be made.

To power the GSM Dialer you can use the auxiliary output on your Texecom panel.  The positive (+) terminal is connected to one of the VIN terminals (the lower one is best as it has on-board thermal fuse protection) and the negative (-) terminal to GND on the GSM Dialer PCB.  You then connect the ‘B’ (bell -ve) terminal to input A or B.

Wiring a GSM Dialer to the Texecom Compact R8 Alarm Panel

GSM Dialer to Texecom Compact R8 Panel

Advent Controls

The GSM Dialler is available from our online shop here

GSM Dialer

GSM Alarm Auto-dialer